■ General Information
Delivers stable metering performance in gas usage environments.
Through the G10A/G16A, G10/G16, and G25 product series, it covers a wide range of flow rates according to usage volume, and long-standing technical expertise has enabled high durability and reliable metering performance.
■ Product Features
● Localized (domestic) design and manufacturing technology optimized for the domestic gas usage environment
● Long-term high durability and stable metering performance achieved through extensive technical know-how
● Diverse product lineup including compact types G10A/G16A, G10/G16, and G25
● Supports convenient wireless metering and efficient data management by integrating with BLE/AMI-based remote meter reading systems
● Product configuration adaptable to a variety of on-site piping and installation conditions

| Item |
G10 |
G16 |
Maximum Flow Rate
Qmax (m³/h) |
16 |
25 |
Transitional Flow Rate
Qt (m³/h) |
1.6 |
2.5 |
Minimum Flow Rate
Qmin (m³/h) |
0.1 |
0.16 |
| Cyclic Volume (dm³) |
6 |
6 |
Maximum Indicated Value
(m³) |
999999.99 |
999999.99 |
Minimum Indicated Value
(dm³) |
0.2 |
0.2 |
Maximum Working
Pressure (kPa) |
50 |
50 |
| 100 |
100 |
Operating Temperature
(°C) |
-25~55 |
-25~55 |
| Inlet/Outlet Thread |
PF 2" |
PF 2" |
Inlet/Outlet Distance
(mm) |
280 |
280 |
| Weight (kg) |
6.7 |
6.7 |
Maximum
Permissible
Error (MPE) |
Qmin ≤ Q < Qt |
±3% |
±3% |
| Qt ≤ Q ≤ Qmax |
±1.5% |
±1.5% |

| Item |
G10 |
G16 |
| H (mm) |
330 |
330 |
| W (mm) |
405 |
405 |
| C (mm) |
280 |
280 |
| D1 (mm) |
113 |
113 |
| D2 (mm) |
240 |
240 |
| Meter Connection |
PF 2" |
PF 2" |